6 research outputs found

    Design, Characterization, and Validation of the OpenWrist Exoskeleton

    Get PDF
    Robotic devices have been clinically verified for use in long duration and high intensity rehabilitation needed for motor recovery after neurological injury. Targeted and coordinated hand and wrist therapy, often overlooked in rehabilitation robotics, is required to regain the ability to perform activities of daily living. To this end, a new coupled hand-wrist exoskeleton has been designed. This thesis details the design of the wrist module and several human-related considerations made to maximize its potential as a coordinated hand-wrist device. The serial wrist mechanism has been engineered to facilitate donning and doffing for impaired subjects and to insure compatibility with the hand module in virtual and assisted grasping tasks. Several other practical requirements have also been addressed, including device ergonomics, clinician-friendliness, and ambidextrous reconfigurability. The wrist module's capabilities as a rehabilitation training device are quantified experimentally in terms of functional workspace and dynamic properties. Finally, the device is validated as an rehabilitation assessment tool by considering its impact on commonly used assessment metrics. The presented wrist module's performance and operational considerations support its use in a wide range of future clinical investigations

    Separating haptic guidance from task dynamics: A practical solution via cutaneous devices

    Get PDF
    There is much interest in using haptic feedback for training new skills or guiding human movement. However, the results of studies that have incorporated haptic guidance to train new skills are mixed, depending on task complexity and the method by which the haptic guidance is implemented. Subjects show dependency on the guidance forces and difficulty in discerning which aspects of the haptic feedback are related to the task dynamics and which are meant to convey task completion strategies. For these reasons, new methods to separate haptic cues for guidance from haptic feedback of task dynamics are needed. In this experiment, 30 subjects completed a trajectory following task using a wrist exoskeleton which also rendered task forces. To assist subjects, guidance cues were provided in one of three forms: (1) cutaneous forces from a wearable skin-stretch device on the ipsilateral forearm and (2) contralateral forearm, and (3) kinesthetic forces from a kinematically similar wrist exoskeleton operated by the contralateral arm. The efficacies of each guidance condition are compared by examining subject performance and learning rates. The results indicate that cutaneous guidance is nearly as effective as kinesthetic guidance, making it a practical and cost-effective alternative for spatially separated assistance

    Spatially Separating Haptic Guidance from Task Dynamics through Wearable Devices

    No full text
    Haptic devices have a high potential for delivering tailored training to novices. These devices can simulate forces associated with real-world tasks, or provide guidance forces that convey task completion and learning strategies. It has been shown, however, that providing both task forces and guidance forces simultaneously through the same haptic interface can lead to novices depending on guidance, being unable to demonstrate skill transfer, or learning the wrong task altogether. This work presents a novel solution whereby task forces are relayed via a kinesthetic haptic interface, while guidance forces are spatially separated through a cutaneous skin stretch modality. We explore different methods of delivering cutaneous based guidance to subjects in a dynamic trajectory following task. We next compare cutaneous guidance to kinesthetic guidance, as is traditional to spatially separated assistance. We further investigate the role of placing cutaneous guidance ipsilateral versus contralateral to the task force device. The efficacies of each guidance condition are compared by examining subject error and movement smoothness. Results show that cutaneous guidance can be as effective as kinesthetic guidance, making it a practical and cost-effective alternative for spatially separated assistance

    Design and characterization of the OpenWrist: A robotic wrist exoskeleton for coordinated hand-wrist rehabilitation

    No full text
    Robotic devices have been clinically verified for use in long duration and high intensity rehabilitation needed for motor recovery after neurological injury. Targeted and coordinated hand and wrist therapy, often overlooked in rehabilitation robotics, is required to regain the ability to perform activities of daily living. To this end, a new coupled hand-wrist exoskeleton has been designed. This paper details the design of the wrist module and several human-related considerations made to maximize its potential as a coordinated hand-wrist device. The serial wrist mechanism has been engineered to facilitate donning and doffing for impaired subjects and to insure compatibility with the hand module in virtual and assisted grasping tasks. Several other practical requirements have also been addressed, including device ergonomics, clinician-friendliness, and ambidextrous reconfigurability. The wrist module's capabilities as a rehabilitation device are quantified experimentally in terms of functional workspace and dynamic properties. Specifically, the device possesses favorable performance in terms of range of motion, torque output, friction, and closed-loop position bandwidth when compared with existing devices. The presented wrist module's performance and operational considerations support its use in a wide range of future clinical investigations

    Assessing Wrist Movement with Robotic Devices

    No full text
    Robotic devices have been proposed to meet the rising need for high intensity, long duration, and goal-oriented therapy required to regain motor function after neurological injury. Complementing this application, exoskeletons can augment traditional clinical assessments through precise, repeatable measurements of joint angles and movement quality. These measures assume that exoskeletons are making accurate joint measurements with a negligible effect on movement. For the coupled and coordinated joints of the wrist and hand, the validity of these two assumptions cannot be established by characterizing the device in isolation. To examine these assumptions, we conducted three user-in-the-loop experiments with able-bodied participants. First, we compared robotic measurements to an accepted modality to determine the validity of joint- and trajectorylevel measurements. Then, we compared those movements to movements without the device to investigate the effects of device dynamic properties on wrist movement characteristics. Lastly, we investigated the effect of the device on coordination with a redundant, coordinated pointing task with the wrist and hand. For all experiments, smoothness characteristics were preserved in the robotic kinematic measurement and only marginally impacted by robot dynamics, validating the exoskeletons for use as assessment devices. Stemming from these results, we propose design guidelines for exoskeletal assessment devices

    Assessing Wrist Movement with Robotic Devices

    No full text
    Robotic devices have been proposed to meet the rising need for high intensity, long duration, and goal-oriented therapy required to regain motor function after neurological injury. Complementing this application, exoskeletons can augment traditional clinical assessments through precise, repeatable measurements of joint angles and movement quality. These measures assume that exoskeletons are making accurate joint measurements with a negligible effect on movement. For the coupled and coordinated joints of the wrist and hand, the validity of these two assumptions cannot be established by characterizing the device in isolation. To examine these assumptions, we conducted three user-in-the-loop experiments with able-bodied participants. First, we compared robotic measurements to an accepted modality to determine the validity of joint- and trajectorylevel measurements. Then, we compared those movements to movements without the device to investigate the effects of device dynamic properties on wrist movement characteristics. Lastly, we investigated the effect of the device on coordination with a redundant, coordinated pointing task with the wrist and hand. For all experiments, smoothness characteristics were preserved in the robotic kinematic measurement and only marginally impacted by robot dynamics, validating the exoskeletons for use as assessment devices. Stemming from these results, we propose design guidelines for exoskeletal assessment devices
    corecore